  • EMC32-S: Immunity level not reached - abort EMS scan

    ...EMC32-S: Immunity level not reached - abort EMS scan Question EMC32-S: Is it possible to abort an EMS scan when the EMC32 goes below a certain immunity level, e.g. if the amplifier fails? Answer Yes, you can do that.  In the EMS Scan Template, on t......

    FAQ - Common Library
    • EMC32-S: Pulse train support in EMC32

      ...EMC32-S: Pulse train support in EMC32 Question: I am using EMC32. How can I configure a test template with the SMB100A (including SMB-K27) or the SMF100A (including SMF-K27) to generate pulse trains for my EMC32 application? Answer: The pulse train......

      FAQ - Common Library
      • FSx doesn't recognize active probe RT-ZS30

        ...FSx doesn't recognize active probe RT-ZS30 Question: We have an issue with our FSx and the RT-ZS30 probe: the FSx does not automatically recognize the probe Could you please help us to solve this blocking issue. Answer: You can work wit......

        FAQ - Common Library
        • Web interface allows several users to control the HMP

          ...Web interface allows several users to control the HMP Question: The HMP is used by two persons at the same time. One is using channel 1 and the other is using channel 2. Are they able to remotely control their channels at the same time via the web interface? ......

          FAQ - Common Library
          • How to connect HMExplorer to the instrument

            ...How to connect HMExplorer to the instrument Question: My HMExplorer does not connect to the instrument Error when adding a device. The interface could not be opened. Answer: The latest version of the H......

            FAQ - Common Library
            • Changing virtual COM port to use field probe with EMC32

              ...Changing virtual COM port to use field probe with EMC32 Question: We are using EMC32 software for EMS measurements. Currently we have difficulties integrating a field probe. We cannot change the COM port of the field probe's USB/serial adapter and therefore cannot use the field......

              FAQ - Common Library
              • Advantest: Initialization Procedure for Many Advantest Products

                ...Advantest: Initialization Procedure for Many Advantest Products Question Reset/Factory Preset / Initialization of Advantest Products Answer ADVANTEST Products Type: TR2114/TR2731/TR2723/R3261/R3361/R3265/R3271/R3273/R3267/R3465/R3163/R3272/R375......

                FAQ - Common Library
                • Computer Name: Default computer name

                  ...Computer Name: Default computer name Question I want to connect to the AFQ via LAN. What is the default computer name? Answer The default computer name is made up of the following components: 'RS' + product name + serial number For example, the......

                  FAQ - Common Library
                  • Programming the AM300 in LabView

                    ...Programming the AM300 in LabView Question This FAQ provides examples of the following: 1. Performing a triangle function (manual trigger) 2. Positive pulse (manual trigger) 3. Positive pulse (external trigger) 4. Output of 100 sinewave periods (manual trigger) The examples......

                    FAQ - Common Library
                    • Connecting the R&S AM300 to R&S WinIQSIM

                      ...Connecting the R&S AM300 to R&S WinIQSIM Question How to run the R&S AM300 in conjunction with R&S WinIQSIM Answer The R&S AM300 needs the R&S AM300-K3 option (key code). R&S AM300-K1 is mandatory, at least version 2.1. Use the recommended insta......

                      FAQ - Common Library